What is Air Sampling Fire Detection? |
![]() |
|
|
Air Sampling, also know as aspirating, fire detection utilizes an aspirator, and a supervised sample pipe network to return air samples from an environment that is being protected, back to a detection unit for analysis. The air sample is drawn into the pipe network through either holes drilled in the pipe, a capillary or extended drop from the pipe, or sample heads which can be either adjustable or non-adjustable. Each of these methods use flow calculations to determine sample hole sizes, pressure drops and acceptable pipe lengths to be sure the system meets NFPA guidelines. Below are details for each of these methods |
|
|
|
Why ProSeries? |
||
|
The new advanced CCD (Cloud Chamber Detection) technology from Protec combines the benefits of spot, laser, and cloud chamber detection into a single detector. Unlike laser and conventional systems, ProSeries detectors using CCD technology only detect combustion. CCD technology is immune to false alarms from dirt, dust, temperature and humidity which plague other early warning air sampling and spot detectors. |
||
![]() |
Before Smoke
No False Alarms Detects in All Four Stages of Fire *Obscuration (obs/ft) - Percentage of light decrease per foot |
|
|
|
|
Three Aspirator Options to Suit Your Application |
|
ProSeries detectors are available with several aspirator options for optimal performance. In addition to new detection technologies, a larger aspirator means more power and greater performance for special hazard applications. |
![]() |
|
|
|
Widest Range of Detectors to Fit Your Specific Needs |
|
No one detector can meet the needs of every application. Determining the proper detector for your application is critical since no two applications are alike. With three aspirator types, multiple zones, multifunction LCD display and multiple networking options, ProSeries offers a detector right for your application. |
|
|
|
|
|
|
Scanning
|
||||
|
Single Zone Up to 10,000 sqft. Without Display |
|
Single Zone Up to 20,000 sqft. Without Display |
|
Single Zone Up to 20,000 sqft. With Display |
1, 2, 3, or 4 Zones Up to 20,000 sqft. With LCD Display |
||
|
|
|
|
|
Scanning |
||||
|
Single Zone. Up to 20,000 sqft. Without Display |
|
Single Zone Up to 20,000 sqft. With LCD Display |
|
1, 2, 3, or 4 Zones Up to 20,000 sqft. With LCD Display |
||
|
|
|
Scanning |
|
Difficult Environments Freezer Warehouses Power Generation Archive Storage High Ceilings Industrial Atriums |
||
|
1, 2, 3, or 4 Zones Up to 43,200 sqft. With LCD Display Largest Aspirator Available Longest Pipe Runs Possible Up to 115 Ceiling Heights |
||||